Testing Facilities

Testing Options
A number of initiatives in the evolution of technology are leading both to higher accuracy and also greater efficiency in gear performance, synchronizing with the latest technology, Triveni conducts various tests to ensure AGMA , API-613 & 677 specifications

The demanding AGMA, API-613 & 677 specifications are followed by adhering to rigorous performance test criteria and its latest data acquisition system, fully instrumental test rig for full speed testing up to 50 MW gear boxes.

We have already tested gearboxes of capacity upto 38 MW in our manufacturing unit at Mysore. Besides, we have enhanced our Test rig capability to test Gear Boxes upto 50 Mw. This further assists us to monitor and record all gear box test results, giving a complete analysis of bearing temperatures, vibration frequencies, frequency spectrum, oil flow and noise.

We offer other test options which include: Back-to-Back Locked Torque Testing, Slow Roll Full Torque Tests for units that have high power intake.


The Monitoring Systems:
  • Automatic Data Acquisition
  • Sound, Temperature, Vibration
  • Oil temperature, pressure, flow
Test Stand Specifications:
  • 1,000 KW D C drive motor.
  • Lube system capacity upto 1000 LPM
  • Seven fully instrumented test cells
  • Documentation packages according to API 613, API 677, and customer specifications available.